world-map

Contact us

Flyout Form

Maximum file size: 16.78MB

Disclaimer

Mattr Inc. is committed to protecting and respecting your privacy, and we’ll only use your personal information to administer your account and to provide the products and services you requested from us. From time to time, we would like to contact you about our products and services, as well as other content that may be of interest to you. If you consent to us contacting you for this purpose, please tick below to say how you would like us to contact you:

Menu Map
Customer Success Story

RTD Cable Assembly Failure & Replacement at a major Canadian Nuclear Power Plant

Premise

A major nuclear power plant operator in Canada supplying 30% of New Brunswick’s electricity was experiencing frequent failure with their RTD assemblies, that put the operation of the plant at risk. Like many CANDU plants around the world, Resistance Temperature Detectors (RTDs) connector assemblies are used in critical temperature measurement loops.

Challenge and Solution

RTD cable assemblies are exposed to extreme temperatures and radiation. The boot on existing RTDs would separate from the connector causing it to bend up to 90o. As a result, the RTD circuit loop would either short or open. This prohibited the RTDs from accurately measuring the process temperatures
Kanata redesigned the RTD Cable Assembly. The new design used a 45o rigid backshell instead of the boot. The rigid backshell reduced the strain between the connector and cables. The cable assembly was also hermetically sealed.

Results

The new design was successfully EQ qualified for 30 years. The RTD Cable Assembly has not failed in service and is far exceeding administrative limits and past operational experience. The success of the new design led to all CANDU NPP operators to switch to the new design. Kanata regularly supplies RTD Cable Assemblies to CANDU Operators around the world.